Water Reuse with MBR, Ultrafiltration and Reverse Osmosis

Treat wastewater once more and use it again for irrigation, washing, toilet flushing, cooling towers and boilers, with Toray membranes shipped from Florida.

Where reused water goes

Each use needs a different water quality. The treatment train follows from the use.

  • Irrigation

    Landscaping, green areas, golf courses and agriculture. Filtration and disinfection are the minimum; the salts in the water matter for the soil and the plants.

  • Washing

    Vehicle and equipment washing, floor and yard cleaning, and dust control on roads and work sites.

  • Toilet flushing

    Hotels, office buildings and housing developments can treat their own wastewater with an MBR and send it back to the toilets through a separate network.

  • Cooling tower makeup

    Cooling towers use a large share of a plant's water. Reused water with low suspended solids, and reverse osmosis where hardness or salts are high, cuts the fresh water they draw.

  • Boiler and process water

    After ultrafiltration, reverse osmosis removes the dissolved salts, so reused water can feed boilers and processes that need purer water.

A typical reuse treatment train

Not every use needs every stage. Irrigation may stop after filtration and disinfection; boiler and process water need reverse osmosis.

  1. Biological treatment

    Bacteria break down the organic matter in the wastewater, in an MBR or in a conventional activated sludge plant with a clarifier.

  2. Membrane filtration

    In an MBR the submerged Toray membranes already filter the water. After a conventional clarifier, Toray UF modules retain the remaining suspended solids, bacteria and viruses.

  3. Reverse osmosis

    When the use needs water low in dissolved salts, reverse osmosis removes them. An antiscalant dosed ahead of the membranes keeps scale from forming.

  4. UV disinfection

    A UV sterilizer inactivates bacteria and viruses before the water is stored or distributed, without adding chemicals to the water.

Protecting the membranes

  • Why UF or MBR before RO

    Reverse osmosis membranes foul quickly with suspended solids and bacteria. UF or MBR permeate is low in turbidity and solids, so the RO runs longer between cleanings. Toray's F-HFUG-2020AN is made for integrated UF and RO systems, and the HFUG-2020HN and TUF rack connect directly to RO without a break tank.

  • Antiscalants and cleaners

    Antiscalants for RO, including one for high silica water, and acid and alkaline cleaners to restore membranes fouled by scale or organic matter.

  • Replacement membranes

    Reverse osmosis membranes in stock, Toray UF modules and Toray MBR cassettes for existing systems. Send us the model you have and we confirm the replacement.

  • Same-day shipping

    Stock orders leave Pembroke Park, Florida, the day they are placed, to sites across the United States and for export to Latin America and the Caribbean.

Toray membranes for water reuse

  • Toray® MBR Membrane Module NHP210

    Toray NHP210 submerged MBR module: 300 or 600 elements, 210 or 420 m² (2,260 or 4,521 ft²) of membrane, 0.08 µm PVDF flat-sheet membranes for municipal and industrial wastewater treatment and reuse.

    • NHP210-300S
    • NHP210-600D
  • Toray® MBR Membrane Module NHPA150

    Toray NHPA150 submerged MBR module: 150 to 600 elements, 105 to 420 m² (1,130 to 4,521 ft²) of membrane, 0.08 µm PVDF flat-sheet membranes for municipal and industrial wastewater treatment and reuse.

    • NHPA150-1C
    • NHPA150-2C
    • NHPA150-3C
    • NHPA150-4C
    • NHPA150-1F
    • +3 more
  • Toray® Ultrafiltration Membrane Module F-HFUG-2020AN

    Toray UF module with 0.005 µm pores for integrated UF–RO systems: 90 m² (969 ft²), up to 15 m³/h (66 gpm), same size as the HFUG-2020AN.

    • F-HFUG-2020AN
  • Toray® Ultrafiltration Membrane Module HFUG-2020HN

    High-pressure Toray UF module for direct coupling to RO: 90 m² (969 ft²) of 0.01 µm PVDF, up to 15 m³/h (66 gpm), 600 kPa (87 psi) maximum inlet pressure.

    • HFUG-2020HN
  • Toray Ultrafiltration(UF) Rack

    Pre-engineered Toray TUF rack with piping for 4 to 28 HFUG-2020HN/RN UF modules, rated 600 kPa (87 psi) for direct connection to reverse osmosis.

    • Modules
    • Modules per rack
    • Area per module
    • Nominal pore size
    • Maximum inlet pressure
    • +3 more
  • Toray TMH Series Ultra-Low-Pressure RO Membranes – 4" & 8" (TMH10A, TMH20A-400C, TMH20A-440C)

    Toray TMH series ultra-low-pressure (ULP) reverse osmosis membrane elements deliver high permeate output at reduced operating pressure, lowering…

  • Toray® Membranes

    SEA WATER MEMBRANES BY TORAY® ALSO AVAILABLE

    • TMG-10D
    • TM-710D
    • TMRO-4040HS
    • TM-810V
    • TMG-20D-400
    • +6 more

Catalog pages

What to send us for a quote

The more of this you can send, the faster and closer the quote. If you do not have a water analysis, tell us and we will say what to measure.

Water analysis
Analysis of the wastewater or of the treated water you want to reuse, including suspended solids, BOD, total dissolved solids, hardness and silica.
Flow
Average and peak flow available, and how much water each use needs.
Use of the water
Irrigation, washing, toilet flushing, cooling towers, boilers or process, and the quality each one needs.
Existing treatment
Whether there is already a biological plant or an MBR, and its type.
Local requirements
The water quality the intended use needs.
Location
Country and nearest port or city, to plan shipping.

Related industries and applications

Common questions

What treatment does wastewater need to be reused?

It depends on the use. Irrigation and washing usually need biological treatment, filtration and disinfection. Cooling towers, boilers and processes usually also need reverse osmosis to remove dissolved salts.

Why use ultrafiltration or MBR before reverse osmosis?

Treated wastewater still carries suspended solids and bacteria that foul reverse osmosis membranes. UF or MBR membranes retain them, so the RO needs fewer cleanings and the membranes last longer.

Can an existing wastewater plant be upgraded for reuse?

Often yes. After a conventional clarifier, Toray UF modules can be added as tertiary filtration, followed by reverse osmosis and UV where the use requires them. Send us the plant's flow and the analysis of its effluent.

Do you sell replacement membranes for reuse systems?

Yes. We stock reverse osmosis membranes and supply Toray ultrafiltration modules and MBR cassettes, along with antiscalants and membrane cleaners. Send us the model of your current membrane and we confirm the replacement.

Do you ship to Latin America?

Yes. We ship from Florida to sites across the United States and export to Latin America and the Caribbean. Quotes and data sheets are available in English and Spanish.

Need a price or help choosing a part?

Tell us the part number or what you are trying to fix. We answer in English and Spanish and ship the same day from Pembroke Park, Florida.